SV Family -- With Superior Surge Survival™


Features:
  • Optically isolated
  • LED status indicator
  • Clear safety cover included
  • 800 volt blocking voltage (3V models)
  • 1200 volt blocking voltage (6V models)
  • 4000 volt isolation
  • Zero voltage turn-on
  • Improved built-in snubber
  • High surge capability
  • 100% tested at rated current
  • U.L. recognized
  • C.S.A. certified
  • CE compliance
Click Here For:

Input:
4 to 32 VDC
Model
->
SVDA/
3V10
SVDA/
3V25
SVDA/-
3V50
SVDA/-
3V75
SVDA/-
6V50
SVDA/-
6V75
Schematic Number 1 1 1 1 1 1
Impedance (Rc) Ohm 1500 1500 1500 1500 1500 1500
Turn-on Voltage (Min.) VDC 4V@5.4mA 4V@5.4mA 4V@3.5mA 4V@3.5mA 4V@3.5mA 4V@3.5mA
Turn-on Voltage (Max.) VDC 32V@10mA Max (current limited) 32V@10mA Max (current limited) 32V@6.5mA Max (current limited) 32V@6.5mA Max (current limited) 32V@6.5mA Max (current limited) 32V@6.5mA Max (current limited)
Turn-off Voltage (Max.) VDC 1 1 1 1 1 1
Reverse Voltage Protection VDC -75 -75 -75 -75 -75 -75

Input: 100 to 280 VAC Model
->
SVAA/
3V10
SVAA/
3V25
SVAA/
3V50
SVAA/
3V75
SVAA/
6V50
SVAA/
6V75
Schematic Number 0 2 2 2 2 2 2
Impedance (Rc) KOhm 20 20 20 20 20 20
Turn-on Voltage (Min.) VAC 100 100 100 100 100 100
Turn-off Voltage (Max.) VAC 20 20 20 20 20 20
Reverse Voltage Protection   N/A N/A N/A N/A N/A N/A

Output: (For All Models)
IOUT (Continuous w/proper heatsink) ARMS 10 25 50 75 50 75
Voltage Drop @ IOUT VAC 1.1 1.2 1.3 1.1 1.3 1.1
ISURGE - 1 Cycle Non-repetitive APEAK 100 250 650 950 650 950
ISURGE - 1 Second Non-repetitive APEAK 40 100 130 140 130 140
Voltage Range (VOUT) VAC 24-330 24-330 24-330 24-330 24-660 24-660
Peak Blocking Voltage   800 800 800 800 1200 1200
Frequency Range Hz 47-63 47-63 47-63 47-63 47-63 47-63
Leakage @ VOUT (max.) mA 8 8 8 8 8 8
Turn-on (max.)   1/2 cycle 1/2 cycle 1/2 cycle 1/2  cycle 1/2 cycle 1/2 cycle
Turn-off (max.)   1/2 cycle 1/2 cycle 1/2 cycle  1/2 cycle 1/2 cycle 1/2 cycle
Holding current (min.) mA 50 50 50 50 50 50
Zero voltage switching   Yes Yes Yes Yes Yes Yes
Dv/Dt @ VOUT (max.) Vus 750 750 1000 1000 500 500
Commutating Dv/Dt
Snubbed for Power Factor.=
  .5 .5 .5 .5 .5 .5
I2T Fusing (8.3 ms.) A2S 35 260 1035 3745 1035 3745
Thermal resistance R0JC (Tj=115oC) 0C/W 1.48 1.05 .65 .30 .65 .65

General Characteristics:
Dielectric strength (Input-Output-Base) VRMS 4000 4000 4000 4000 4000 4000
Capacitance Input to Output pf 3 3 3 3 3 3
Ambient temp. range (Operating) 0C -40 to +100 -40 to +100 -40 to +100 -40 to +100 -40 to +100 -40 to +100

Adequate heatsinking, including consideration of air temperature and flow, is essential to the proper operation of a solid state relay. Units should not be mounted in an enclosed area without proper air flow. Units should also never be mounted to a plastic base or to a painted surface. Proper thermal transfer gel or pad should be applied to the heatsink before mounting the relay. Failure to provide adequate heatsinking will cause a solid state relay to fail.